PMI Series are designed for installation in the piping. This unit must be installed vertically. In this, the motor is directly attached to macerator chamber to form a single unit. Inside the Macerator, the impeller with replaceable cutting edges, rotates inside the stationary cutting ring, which macerate the particles to smaller size. For this model either the helical pump or progressive cavity pump must be installed to suck the solids through the macerator and pump them into the plant for further treatment.
Flange positions Suction & Delivery Flange :Â Opposite, inline and same Dimension Flange Design Connection dimensions as per DIN StandardCross Sectional View
Sl.No. | Macerator type | Inlet dia (mm) | Outlet dia (mm) | Cutting ring dia(mm) | Max. throughput at 3% dry. substance (m 3/h) | Speed (rpm) | Drive capacity(kW/HP) | Delivery head(m) | Weight (kg) Approx |
1 | PMI 10 | 125 | 125 | 200 | 10 | 1500 | 4/5.5 | 3 | 190 |
2 | PMI 20 | 125 | 125 | 200 | 20 | 1500 | 5.5/7.5 | 195 | |
3 | PMI 40 | 150 | 150 | 300 | 40 | 1000 | 7.5/10 | 330 | |
4 | PMI 80 | 150 | 150 | 300 | 80 | 1000 | 11/15 | 340 |
Macerator type | Unit Dimensions | Extension Measurement | External sealing | |||||||||||
a1 | a2 | a3 | a4 | b1 | h1 | h2 | d1 | d2 | d3 | d4 | d5 | X | S1 | |
PMI 10 | 190 | 843 | 342 | 501 | 310 | 500 | 470 | 380 | 277 | 228 | 260 | 22 | 300 | M16 |
PMI 20 | 190 | 843 | 342 | 501 | 310 | 500 | 470 | 380 | 277 | 228 | 260 | 22 | 300 | M16 |
PMI 40 | 210 | 1044 | 375 | 670 | 310 | 700 | 470 | 480 | 377 | 325 | 360 | 22 | 400 | M16 |
PMI 80 | 210 | 1044 | 375 | 670 | 310 | 700 | 470 | 480 | 377 | 325 | 360 | 22 | 400 | M16 |
Macerator type | connection dimensions according to DIN 2501, PN 10 | |||||
PN1 PN2 | D | Pf | k1 | g1 | No.of holes | |
PMI 10 | 125 | 254 | 26 | 210 | 18 | 8 |
PMI 20 | 125 | 254 | 26 | 210 | 18 | 8 |
PMI 40 | 150 | 285 | 26 | 240 | 22 | 8 |
PMI 80 | 150 | 285 | 26 | 240 | 22 | 8 |